Cisco Cisco Packet Data Gateway (PDG) Guia De Resolução De Problemas

Página de 5302
PDSN Service Configuration Mode Commands   
▀  threshold a11-rrp-failure 
 
▄  Cisco ASR 5000 Series Command Line Interface Reference 
OL-22948-01   
threshold a11-rrp-failure 
Set an alarm or alert based on the number of A11 Registration Response failures for the PDSN service. 
Product
 
PDSN 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Deletes the alert or alarm. 
Default: 0 
The high threshold number of A11 Registration Response failures that must be met or exceeded within the 
polling interval to generate an alert or alarm. It can be configured to any integer value between 0 and 100000. 
Default:0 
The low threshold number of A11 Registration Response failures that must be met or exceeded within the 
polling interval to clear an alert or alarm. It can be configured to any integer value between 0 and 100000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
Use this command to set an alert or an alarm when the number of A11 Registration Response failures is equal 
to or greater than a specified number. 
Alerts or alarms are triggered for the number of A11 Registration Response failures based on the following 
rules: 
 
Enter condition: Actual number of A11 Registration Response failures > High Threshold 
 
Clear condition: Actual number of A11 Registration Response failures £ Low Threshold 
Example 
The following command configures a number of A11 Registration Response failures threshold of 
 and a low 
threshold of 
 for a system using the Alarm thresholding model: