threshold a11-rac-msg-discard 
Set an alarm or alert based on the number of Discarded A11 Registration Acknowledgements for the PDSN service. 
Product
 
PDSN 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Deletes the alert or alarm. 
Default: 0 
The high threshold number of Discarded A11 Registration Acknowledgements that must be met or exceeded 
within the polling interval to generate an alert or alarm. It can be configured to any integer value between 0 
and 100000. 
Default:0 
The low threshold number of Discarded A11 Registration Acknowledgements that must be met or exceeded 
within the polling interval to clear an alert or alarm. It can be configured to any integer value between 0 and 
100000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
Use this command to set an alert or an alarm when the number of Discarded A11 Registration 
Acknowledgements is equal to or greater than a specified number. 
Alerts or alarms are triggered for the number of Discarded A11 Registration Acknowledgements based on the 
following rules: 
 
Enter condition: Actual number of Discarded A11 Registration Acknowledgements > High Threshold 
 
Clear condition: Actual number of Discarded A11 Registration Acknowledgements £ Low Threshold 
Example 
The following command configures a number of Discarded A11 Registration Acknowledgements threshold of 
 
and a low threshold of 
 for a system using the Alarm thresholding model: