Cisco Cisco Packet Data Gateway (PDG) Guia De Resolução De Problemas
Global Configuration Mode Commands
threshold cpu-load ▀
Cisco ASR 5000 Series Command Line Interface Reference ▄
OL-22947-02
threshold cpu-load
Configures the threshold for monitoring PAC/PSC/PSC2 CPU loads using a 5 minute average measurement. The
threshold is enabled by enabling CPU resource monitoring.
threshold is enabled by enabling CPU resource monitoring.
Product
All
Privilege
Security Administrator, Administrator
Syntax
Default: 0
If the monitored CPU load is greater than or equal to the specified number an alert is sent.
If the monitored CPU load is greater than or equal to the specified number an alert is sent.
must be an integer from 0 through 15.
Default: 0
This is a low watermark value that sets the alarm clearing threshold value. If not present it is taken from the
first value.
This is a low watermark value that sets the alarm clearing threshold value. If not present it is taken from the
first value.
must be an integer from 0 through 15.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the low threshold.
Usage
Use this command to set an alert when the card‘s CPU load is equal to or greater than the number specified.
Alerts or alarms are triggered for CPU load based on the following rules:
Alerts or alarms are triggered for CPU load based on the following rules:
Enter condition: Actual CPU load ³ High Threshold
Clear condition: Actual CPU load < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
Refer to the
of the polling interval.
Refer to the
command to configure the polling interval and the
command to enable thresholding for this value.
Important:
This command is not supported on all platforms.
Example
To set an alert when the PAC/PSC/PSC2 CPU load is over 10 and set an alert clear when the CPU load drops down
equal or less than 7, enter the following command;
To set an alert when the PAC/PSC/PSC2 CPU load is over 10 and set an alert clear when the CPU load drops down
equal or less than 7, enter the following command;