Cisco Cisco Packet Data Gateway (PDG) Guia De Resolução De Problemas

Página de 5213
  Global Configuration Mode Commands 
threshold dcca-rating-failed  ▀   
Cisco ASR 5000 Series Command Line Interface Reference  ▄  
 
  OL-22947-02 
threshold dcca-rating-failed 
Configures Diameter Credit Control Application (DCCA) Rating Group (content-id) request reject thresholds. 
Product
 
ECS 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Disables the threshold for configured alarm and sets the 
 and 
 values to 0. 
Default: 0 
The high threshold number of requests for a block of credits due to invalid Rating Group (content-id), 
rejected from the Diameter server that must be met or exceeded within the polling interval to generate an alert 
or alarm. 
The number can be configured to any integer value between 0 and 1044000. 
Default: 0 
The low threshold number of requests for a block of credits due to invalid Rating Group (content-id), rejected 
from the Diameter server that maintains a previously generated alarm condition. If the number of errors falls 
beneath the low threshold within the polling interval, a clear alarm will be generated. 
The number can be configured to any integer value between 0 and 1044000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
In the event that the Diameter server rejects the system request for a block of credits due to invalid Rating 
Group, defined as content-id, dcca-rating-failed message is generated. 
Rating Group failed threshold generates alerts or alarms based on the number of requests rejected from 
Diameter server during the specified polling interval. 
Alerts or alarms are triggered for Rating Group failed based on the following rules: 
 
Enter condition: Actual number of DCCA Rating Group failed ³ High Threshold 
 
Clear condition: Actual number of DCCA Rating Group failed < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval.