Cisco Cisco Packet Data Gateway (PDG) Guia De Resolução De Problemas

Página de 1720
show alarm   
▀  show alarm outstanding all verbose 
 
▄  Cisco ASR 5000 Series Statistics and Counters Reference 
OL-22990-02   
show alarm outstanding all verbose 
Table 100. 
show alarm outstanding all verbose
 Command Output Descriptions 
Field
 
Description
 
Severity 
(Sev) 
If an alarm is present, the system will indicate that one of the following alarm levels has been triggered: 
 
Minor (MN): This alarm is triggered when a high temperature is detected on a card causing the fan tray to 
switch to high speed. 
 
Major (MJ): This alarm is triggered on the following conditions: 
 
A hardware failure was detected on a card that will cause it to be taken off-line 
 
One of the Power Filter Units has failed or was removed. 
 
One or more of the fans on either the upper or lower fan tray have failed. 
 
Either the upper or lower fan trays have been removed. 
 
Critical (CR): This alarm is triggered when events cause a degradation in service (i.e. the system is 
supporting a large number of subscribers and Processing Cards are removed thus reducing the amount of 
available CPU and memory resources). 
Object 
Describes the object that triggered the alarm event 
Event 
Describes the event that triggered the alarm condition. 
Timestamp 
Lists the date and time that the alarm condition was triggered. 
Alarm ID 
The internal system ID of the alarm.