Troubleshooting the  System   
▀  Detecting Faulty Hardware Using Component LEDs 
 
▄  Cisco ASR 5000 Series System Administration Guide 
OL-22969-02   
Color
 
Description
 
Troubleshooting
 
None
 
PFU is not receiving 
power
 
 
Verify that the power switch is in the ON position. 
 
Verify that the RTN and -VDC lugs are attached properly according to the 
instructions provided in this document. 
 
Verify that the ground lug is attached properly.Verify that the power source is on 
and is supplying the correct voltage and sufficient current. 
 
Check the cables from the power source to the rack for continuity. 
 
If a fuse panel is installed between the power distribution frame (PDF) and the 
chassis, verify that the fuses are intact. 
 
If a fuse panel is installed between the PDF and the chassis, check the cables from 
the fuse panel to the chassis for continuity. 
 
If all of the above suggestions have been verified, then it is likely that the PFU is 
not functional. Please contact your service representative. 
 
 
Checking the LEDs on the SPC(s) 
Each SPC is equipped with the following LEDs : 
 
 
 
RUN/FAIL 
 
Active 
 
Standby 
 
Status 
 
Service