Cisco Cisco Packet Data Gateway (PDG) Guia De Resolução De Problemas

Página de 322
  Troubleshooting the  System 
Taking Corrective Action  ▀   
Cisco ASR 5000 Series System Administration Guide  ▄  
 
  OL-22969-02 
Check the entry in the Oper State column next to the PAC/PSC that was just migrated from. Its state should 
be Standby. The state of the PAC/PSC migrated to should be Active
 
Manually Initiating a Line Card Switch 
 
Line cards are installed in the half-height slots at the rear of the chassis. This design allows for two line cards (both 
Ethernet 10/100 both Ethernet 1000 (or both QGLCs on an ASR 5000)) to be installed behind every application card. 
When two line cards are installed, as the application card that they are installed behind is booted, the card in the upper-
rear chassis slot will automatically be made active while the card in the lower-rear chassis slot will automatically be 
placed in standby mode. In the event that the active card experiences a failure, the system will automatically switch 
traffic to the standby card in the lower slot. 
In the event that a SPIO experiences a failure, the system will automatically switch traffic to the redundant SPIO 
installed behind the redundant SPC/SMC. 
In the event that an issue arises that is not severe enough for the system to perform an automatic switch, a manual switch 
can be performed. Follow the instructions below to manually initiate a line card or SPIO switch. These instructions 
assume you are at the root prompt for the Exec mode: 
Step 1 
Initiate a manual line card or SPIO migration by entering the following command: 
 
Keyword/Variable
 
Description
 
lc 
Specifies that a switch will be done for an Ethernet 10/100 or Ethernet 1000 Line Card (Quad Gig-E (QGLC) 
on an ASR 5000 only). 
spio 
Specifies that a switch will be done for a SPIO. 
to 
Specifies the chassis slot number of the redundant Ethernet 10/100 or Ethernet 1000/QGLC Line Card that is 
being migrated to. Executing this command will switch network connections from the active line card that 
corresponds to the card being migrated to. 
can be any of the following integer values: 17 through 23, 26 through 39, or 42 through 48. 
Important:
  This keyword is only used if the 
 keyword is used. The line card being 
migrated to must be in the standby mode. 
 
 
You will receive the following prompt: