Cisco Cisco Packet Data Gateway (PDG)

Página de 8994
  Channelized Port Configuration Mode Commands 
threshold rx-utilization  ▀   
 
Command Line Interface Reference, StarOS Release 17  ▄  
 
   
2193 
threshold rx-utilization 
Configures thresholds for receive-port utilization. 
Product
 
SGSN 
Privilege
 
Security Administrator, Administrator 
Syntax
 
threshold rx-utilization high_thresh [ clear low_thresh ] 
high_thresh
 
Default: 80 
The high threshold receive port utilization percentage that must be met or exceeded within the polling interval 
to generate an alert or alarm. 
The percentage can be configured to any integer value between 0 and 100. 
clearlow_thresh
 
Default: 80 
Allows the configuration of the low threshold. 
The low threshold receive port utilization percentage that maintains a previously generated alarm condition. 
If the utilization percentage falls below the low threshold within the polling interval, a clear alarm will be 
generated. 
The percentage can be configured to any integer value between 0 and 100. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage 
Receive port utilization thresholds generate alerts or alarms based on the utilization percentage of each 
configured port in relation to data received during the specified polling interval. This threshold is configured 
on a per-port basis. 
Important:
  Ports configured for half-duplex do not differentiate between data received and data transmitted. 
Therefore, to avoid redundant alarms, it is recommended that only the receive or transmit utilization threshold be 
configured. 
Alerts or alarms are triggered for receive port utilization based on the following rules: 
 
Enter condition: Actual percent utilization of a port for received data ³ High Threshold 
 
Clear condition: Actual percent utilization of a port for received data < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval.