Cisco Cisco Packet Data Gateway (PDG)

Página de 8994
  ORBEM Configuration Mode Commands 
event-notif-service  ▀   
 
Command Line Interface Reference, StarOS Release 17  ▄  
 
   
7415 
event-notif-service 
Enables or disables the ORB Notification Service and allows the configuration of filters dictating which event 
notifications are sent. 
Product
 
All 
Privilege
 
Security Administrator, Administrator 
Mode
 
Exec > Global Configuration > ORBEM Configuration 
configure > orbem
 
Entering the above command sequence results in the following prompt: 
[local]host_name(config-orbem)# 
Syntax
 
[ no ] event-notif-service [ filter { event-id event_id [ to final_event_id ] | facility 
event_facility level event_level } ] 
default event-notif-service filter 
default
 
Restores the ORB Notification Service filter to its default behavior of sending all “error” level and higher 
events, and “info” level events for the orbs facility, CLI command logs, and license change logs. 
no
 
Disables the event notification service. 
filter
 
Specifies a filter that determines for which events the system sends notifications. 
event-id
 
event_id
 
[ to
 
final_event_id
 
]
 
Specifies an event filter based on event identification (event ID) number. 
event_id
 is a specific event ID to filter or is the initial event ID in range if the 
to
 keyword is used.  
In 14.1 and earlier releases, 
event_id
 is an integer from 1 through 202699. 
In 15.0 and later releases, 
event_id
 is an integer from 1 through 204999. 
to
 allows the specification of a range of event IDs to filter. When used, 
final_event_id
 specifies the last 
event ID in the range to be filtered. It can be configured to an integer from 1 through 204999, but must be a 
value greater than the initial event ID. 
facility
 
event_facility
 
level
 
event_level
 
Specifies an event filter based on facility type and notification severity level. 
event_facility
 specifies the facility type and can be any one of the following: 
 
a10: A10 interface facility 
 
a11: A11 interface facility