Cisco Cisco Packet Data Gateway (PDG) Folheto
Global Configuration Mode Commands (T-threshold phspc)
threshold call-setup-failure ▀
Cisco ASR 5x00 Command Line Interface Reference ▄
5327
threshold call-setup-failure
Configures call setup failure, alarm or alert thresholds for the system.
Product
All
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold call-setup-failure high_thresh [ clear low_thresh ]
high_thresh
Default: 0
Specifies the high threshold number of call setup failures experienced by the system that must be met or
exceeded within the polling interval to generate an alert or alarm.
Specifies the high threshold number of call setup failures experienced by the system that must be met or
exceeded within the polling interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 100000. A value of 0 disables the threshold.
clear
low_thresh
Default: 0
Specifies the low threshold number of call setup failures experienced by the system that maintains a
previously generated alarm condition. If the number of setup failures falls beneath the low threshold within
the polling interval, a clear alarm will be generated.
Specifies the low threshold number of call setup failures experienced by the system that maintains a
previously generated alarm condition. If the number of setup failures falls beneath the low threshold within
the polling interval, a clear alarm will be generated.
low_thresh
is an integer from 0 through 100000. A value of 0 disables the threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Call setup failure thresholds generate alerts or alarms based on the total number of call setup failures
experienced by the system during the specified polling interval.
Alerts or alarms are triggered for call setup failures based on the following rules:
experienced by the system during the specified polling interval.
Alerts or alarms are triggered for call setup failures based on the following rules:
Enter condition: Actual number of call setup failures is greater than or equal to the high threshold.
Clear condition: Actual number of call setup failures is less than the low threshold.
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end
of the polling interval.
Refer to the
of the polling interval.
Refer to the
threshold poll
command to configure the polling interval and the
threshold monitoring
command to enable thresholding for this value.
Example