Cisco Cisco Packet Data Gateway (PDG) Folheto
PCC-Sp-Endpoint Configuration Mode Commands
profile-data ▀
Cisco ASR 5x00 Command Line Interface Reference ▄
7423
profile-data
This command allows the operator to specify data-reference and service indication AVP values used in UDR/SNR
message for profile data sent over Sp endpoint when access type is set to Diameter.
message for profile data sent over Sp endpoint when access type is set to Diameter.
Product
IPCF
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration > Context Configuration > PCC Sp Endpoint Configuration
configure > context context_name > pcc-sp-endpoint endpoint_name
Entering the above command sequence results in the following prompt:
[context_name]host_name(config-spendpoint)#
Syntax
profile-data key data-reference data_ref_value [service-indication svc_ind_value]
default profile-data key
default
Specifies the data-reference value used in UDR/SNR message for profile data sent over Sp endpoint to
default value of ‘
default value of ‘
0
’ (zero) and service indication AVP value to
profile data
when access type is set to
Diameter in PCC-Sp-Endpoint instance.
data-reference
data_ref_value
Default: 0
Specifies the data-reference values used in UDR/SNR message for profile data sent over Sp endpoint when
access type is set to Diameter in PCC-Sp-Endpoint instance.
The data reference value
Specifies the data-reference values used in UDR/SNR message for profile data sent over Sp endpoint when
access type is set to Diameter in PCC-Sp-Endpoint instance.
The data reference value
data_ref_value
must be an integer from 1 through 65535.
service-indication
svc_ind_value
Specifies the service indication AVP value used in UDR/SNR message for profile data sent over Sp endpoint
when access type is set to Diameter in PCC-Sp-Endpoint instance.
when access type is set to Diameter in PCC-Sp-Endpoint instance.
Important:
The Service-Indication values are set as per application logic and are supposed to be used only with
SSC.
The service indication value
svc_ind_value
must be a string of alpha and/or numeric characters from 1 to
32 characters.