Cisco Cisco Packet Data Gateway (PDG) Guia Do Administrador

Página de 342
  Troubleshooting 
Detecting Faulty Hardware  ▀   
 
Cisco ASR 5500 System Administration Guide  ▄  
 
   
183 
FSC Redundancy LED States 
The Redundancy LED on the FSC indicates that software is loaded on the card, but it is serving as a redundant 
component. FSC support n+1 redundancy; the Redundancy LED should be green on only one FSC for normal system 
operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 26.  FSC Redundancy LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card is in redundant mode
 
None needed. There is at least one FSC in Standby mode. 
Amber
 
Card is not backed up by a 
standby FSC.
 
Check the status of the other FSCs. If one FSC has failed or has been removed 
from the chassis, the system can continue to function but redundancy is 
compromised.
 
Refer to Monitoring the System for information on determining the status of 
the FSC and system software processes.
 
Blinking 
Amber
 
Tasks or processes being migrated 
from an active FSC to the standby 
FSC.
 
Refer to Monitoring the System for information on determining the status of 
the FSC and system software processes. 
None
 
Card is not receiving power. 
OR 
Card has failed. 
Verify that the Run/Fail LED is green. If so, the card is receiving power and 
POST test results are positive. If it is off, refer to 
 for 
troubleshooting information. 
 
FSC Drive 
n
 Activity LED States 
The Drive 1 Activity and Drive 2 Activity LEDs on the FSC indicate that the RAID solid state drives are being accessed 
by the MIO. Drive 1 and Drive 2 on each FSC form a RAID 0 configuration. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information also provided to diagnose the problem. 
Table 27.  FSC Drive
n
 Activity LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Files are being transferred to or 
accessed from the RAID configuration 
by the MIO.
 
None required.
 
None
 
There is no RAID activity. 
OR 
 RAID configuration is unavailable. 
  
None
 
Card is not receiving power
 
Verify that the Run/Fail LED is green. If so, the card is receiving power and 
POST test results are positive. If it is off, refer to 
for 
troubleshooting information.