Cisco Cisco ASR 5000 Guia Do Administrador
HeNB-GW Service Configuration Procedures
▀ Logging Facility Configuration
▄ Cisco ASR 5x00 Home eNodeB Gateway Administration Guide
44
Logging Facility Configuration
Use the following example to configure the HeNB-GW system to enable the logging and debug facilities for HeNB-GW
subscriber and related protocols.
subscriber and related protocols.
Important:
This section provides the minimum instruction set for configuring logging facilities for
system monitoring that allows the user to monitor the events and logging. commands that configure
additional logging facilities are provided in the Exec Mode Command chapter of Command Line Interface
Reference.
additional logging facilities are provided in the Exec Mode Command chapter of Command Line Interface
Reference.
logging filter active facility henbapp level { critical | error | warning | unusual |
info | trace | debug }
info | trace | debug }
logging filter active facility henbgw level { critical | error | warning | unusual | info
| trace | debug }
| trace | debug }
logging filter active facility henbgwdemux level { critical | error | warning | unusual |
info | trace | debug }
info | trace | debug }
logging filter active facility henbgwmgr level { critical | error | warning | unusual |
info | trace | debug }
info | trace | debug }
configure
logging console
logging display event-verbosity {min | concise | full}
logging filter runtime facility henb-gw level { critical | error | warning | unusual |
info | trace | debug }
info | trace | debug }
logging filter runtime facility henbapp level { critical | error | warning | unusual |
info | trace | debug }
info | trace | debug }
logging filter runtime facility henbgwdemux level { critical | error | warning |
unusual | info | trace | debug }
unusual | info | trace | debug }
logging filter runtime facility hnbmgr level { critical | error | warning | unusual |
info | trace | debug }
info | trace | debug }
logging filter runtime facility sctp { critical | error | warning | unusual | info |
trace | debug }
trace | debug }
logging filter runtime facility threshold { critical | error | warning | unusual | info
| trace | debug }
| trace | debug }
Important:
Refer System Administration Guide for more information on logging facility configuration.