Cisco Cisco Aironet 1200 Access Point

Página de 11
   
7
Release Notes for Cisco Aironet 1100, 1130, 1200, 1230, 1240, and 1300 Series Access Points for Cisco IOS Release 12.3(11)JX1
OL-10752-02
Installation Notes
Figure 2
Power Options on the System Software: System Configuration Page
Using the AC Power Adapter
If you use the AC power adapter to provide power to the access point, you do not need to adjust the access 
point configuration.
Using a Switch Capable of IEEE 802.3af Power Negotiation
If you use a switch to provide Power over Ethernet (PoE) to the access point and the switch supports the 
IEEE 802.3af power negotiation standard, select Power Negotiation on the System Software: System 
Configuration page. 
Using a Switch That Does Not Support IEEE 802.3af Power Negotiation
If you use a switch to provide Power over Ethernet (PoE) to the access point and the switch does not 
support the IEEE 802.3af power negotiation standard, select Pre-Standard Compatibility on the 
System Software: System Configuration page. 
Using a Power Injector
If you use a power injector to provide power to the access point, select Power Injector on the System 
Software: System Configuration page and enter the MAC address of the switch port to which the access 
point is connected.
Operating 5-GHz Radio Requires Power Injector, Power Module, or Catalyst 3550-24 PWR Switch
The 1200 series power injector and the 1200 series power module support operation of the 5-GHz radio 
in the access point. Currently, the Catalyst 3550-24 PWR switch supports power for both the 2.4-GHz 
radio and the 5-GHz radio. Other switches and power patch panels might not provide enough power for 
the 5-GHz radio.
Access Point Requires 1200 Series Universal Power Supply and Power Injector
If you use a power injector or a power module to provide power to a 1200 series access point, you must 
use a 1200 series universal power supply. If you need to use a power injector to inject power into the 
access point’s Ethernet port, you must use a 1200 series power injector. The 350 series universal power 
supply and power injector are not compatible with the 1200 series access point.