Cisco Cisco ONS 15216 (EDFA3) Metropolitan Regional DWDM System Guia Da Instalação

Página de 26
Cisco ONS 15216 MD Patch Panel Specifications
This section contains environmental, power, optical, mechanical, and connector specifications for the patch panel.
Environmental and Power Specifications
Table 4: Environmental and Power Specifications for 15216-MD-48-ODD and 15216-MD-48-EVEN
Units
Maximum
Minimum
Environmental Condition
Celsius
65
-5
Continuous Operative
Temperature Range (OTR)
Fahrenheit
149
23
mW
300
Power handling for the optical
port
mW
600
400
Power handling for the USB
Port
Table 5: Environmental and Power Specifications for 15216-MD-48-ODDE and 15216-MD-48-EVENE
Units
Maximum
Minimum
Environmental Condition
Celsius
85
-40
Storage Temperature Range
Fahrenheit
185
-40
Celsius
65
-5
Continuous Operative
Temperature Range (OTR)
Fahrenheit
149
23
%RH
95
5
Operating Humidity
mW
500
Power handling for the each
port
Optical Specifications
Table 6: Optical Specifications for 15216-MD-48-ODD and 15216-MD-48-EVEN
Units
Max
Min
Condition
Parameter
THz
191.4
196.1
Within operative
temperature range
Frequency/Wavelength
Range (Odd Grid
version)
nm
1528.77
1566.31
THz
191.35
196.05
Within operative
temperature range
Frequency/Wavelength
Range (Even Grid
version
nm
1529.16
1566.72
19