The following table shows the manufacturer-specified TAP split ratios for the TAP coupler optical power in the patch panel. The
split ratio denotes the ratio of the TAP input signal to the output signal.
Table 3: Manufacturer-specified TAP Split Ratio
Units
Maximum
Minimum
Condition
Parameter
dB
22
18
Attenuation = IL1 - IL2,
where IL1 = Ch1-RX to
MON-MUX Insertion
Loss and IL2 = Ch1-RX
to COM-TX Insertion
Loss.
Monitor Attenuation
MUX
dB
22
18
COM-RX to
MON-DMX Insertion
Loss
Monitor Attenuation
DEMUX
Safety Information
Before you install, operate, or service this product, you must read the
document for important safety information and warning translations.
This product is compliant with the GR 1089, UL60950 /CSA 22.2 No. 60950-00, and IEC 60950 standards.
Laser Radiation Emission Restrictions
The Class 1M Laser safety and warning label is affixed to this product and indicates that the product should never be used or installed
in an optical network with emissions higher than Class 1M.
Class 1M laser radiation when open. Do not view directly with optical instruments. Statement 281
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams
or view directly with optical instruments. Statement 1051
Warning
Electrical Safety
This product is optically and electrically passive and requires no electrical connections. No electrostatic discharge (ESD) or other
electrical safety considerations apply.
Mounting Brackets and Rack Equipment
The patch panel is two-rack units (RUs) high and can be installed either above or below the DWDM generating equipment according
to the local site practice. Each package includes one set of the following brackets: