Cisco Cisco Prime Optical 9.8 Guia Do Programador

Página de 762
Cisco Prime Optical 9.8 GateWay/CORBA Programmer Reference Guide 
OL-29218-01
 
 
575
 
•  pwClassTable.StaticOAMenabled is false, the pwClassTable.StaticOamClass attribute is 
required, but the content is not passed to the node in the creation command. 
•  pwClassTable.BFDoVCCVEnabled is false, the pwClassTable.BfdTemplate and 
pwClassTable.AcStat attributes are required, but the content is not passed to the node in 
the creation command. 
If pwClass creation or modification fails, an exception is returned if: 
•  The attribute values do not match the attribute description listed in the table. 
•  pwClassTable.Name is empty. 
•  pwClassTable.Interwork is not NONE and pwClassTable.SeqEnabled is true. 
•  pwClassTable.StaticOAMEnabled is true and pwClassTable.StaticOamClass is an empty 
string (""). 
•  pwClassTable.BFDoVCCVEnabled is true and pwClassTable.BfdTemplate is an empty string 
(""). 
•  pwClassTable.BFDoVCCVEnabled is true and pwClassTable.CtrlWord is false. 
•  pwClassTable.Protocol is NONE; and pwClassTable.BFDoVCCVEnabled, 
pwClassTable.StaticOAMEnabled, and pwClassTable.AcStat are true. 
•  pwClassTable.Protocol is LDP and pwClassTable.StaticOAMEnabled is true. 
•  pwClassTable.Protocol is LDP and pwClassTable.StaticOAMEnabled is false and 
pwClassTable.AcStat is true. 
•  pwClassTable.PrefPathEnabled is true, pwClassTable.TunnType is TP, and 
pwClassTable.Protocol is LDP. 
If pwClass deletion fails, an exception is returned if: 
•  The attribute values do not match the attribute description listed in the table. 
•  pwClassTable.Name is empty. 
The following table shows an example of adding a pseudowire class. 
PW 
Clas
s
 
Operati
on Type
 
Enca
ps
 
Protoc
ol
 
Interwo
rk
 
Ctrl 
Wor
d
 
Preferr
ed Path
 
Tunn
el 
Type
 
Tunnel 
Numb
er
 
Enable 
Sequenci
ng
 
Sequenci
ng Mode
 
Pw-
300
 
add
 
MPLS
 
NONE
 
ETHERN
ET
 
true
 
true
 
TP
 
300
 
true
 
TRANSMI
T
 
 
The following table shows an example of deleting a pseudowire class. 
 
PW 
Clas
 
Operati
on Type
 
Enca
ps
 
Protoc
ol
 
Interwo
rk
 
Ctrl 
Wor
d
 
Preferr
ed Path
 
Tunn
el 
Type
 
Tunnel 
Numb
er
 
Enable 
Sequenci
ng
 
Sequenci
ng Mode
 
Pw-
301
 
rem
 
MPLS
 
LDP
 
ETHERN
ET
 
false
 
false
 
TP
 
301
 
true
 
TRANSMI
T