Cisco Cisco Prime Optical 9.6 Guia Do Programador

Página de 818
Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide 
OL-28047-01
 
 
46
 
Secondary States (SST)
 
Attribute Value
 
Meaning
 
DSBLD (Disabled)
 
The entity has been manually removed from service and cannot 
perform its provisioned functions. All of its provisioned services 
are disrupted. Traffic is not carried.
 
LPBK (Loopback)
 
The loopback command is in effect (any loopback type). 
 
2.1.8.4  Topological Links 
Topological links are unidirectional or bidirectional for ONS 15454 SONET NEs. 
2.1.8.5  PTPs 
All PTPs are bidirectional for the ONS 15454 SONET, except for PTPs on DWDM cards (optical 
amplifiers, optical multiplexers, optical demultiplexers, and optical add/drop multiplexers). The 
ports are always in channelized mode. PTPs support IN_SERVICE, OUT_OF_SERVICE, 
OUT_OF_SERVICE_MAINTENANCE, and AUTO_IN_SERVICE values for the service state attribute. 
2.1.8.6  CTPs 
All CTPs are in channelized mode for the ONS 15454 SONET. Alarm monitoring cannot be 
turned on or off for CTPs. 
2.1.8.7  SNCs 
One node supports a maximum of 144 bidirectional STS SNCs with an XC or Cross-Connect 
Virtual Tributary (XCVT) card installed or 576 bidirectional STS SNCs with a 10 Gigabit Cross-
Connect (XC10G) card installed. If an XCVT or XC10G card is present, you can create a maximum 
of 336 bidirectional VT1.5 SNCs. 
The SNC name cannot exceed 48 characters. The NE enforces the SNC name character limit. 
2.1.8.8  Equipment Protection 
1:N equipment protection is supported for DS1, DS3, DS3I, and DS3E cards. You must install 
protect cards (DS1N, DS3N, DS3IN, and DS3NE) in slot 3 or slot 15 on the same side of the shelf 
as the protected cards. Protect cards must match the cards they protect. For example, a DS1N 
protects only DS1 or DS1N cards. You must create the protection group. Installing DS1N or 
DS3N cards in slot 3 or slot 15 does not automatically protect other DS1 or DS3 cards. 1:N 
equipment protection is always revertive. 
1:1 equipment protection is supported for DS1, DS3, DS3I, DS3E, EC-1, and DS3XM cards. Install 
the protect card in an odd-numbered slot and install the working card in an adjacent even-
numbered slot. For example, install the protect card in slot 1 and install the working card in slot 
2. 
2.1.8.9  Facility Protection 
Facility protection is available for OC-n PTPs. Protect ports must match the working ports. For 
example, port 1 on an OC-3 card is protected only by port 1 on another OC-3 card.