Surge-Gap
 Drop Amplifier Quick Install Sheet 
General Installation Notes 
Keep the following in mind when installing the Surge-Gap
 Drop Amplifier. 
• 
The drop amplifier has no power switch. Power is on when the AC adapter is plugged into 
an AC outlet and the power cable is connected to the drop amplifier. 
• 
The power “on” state is indicated by the LED lighting up. 
• 
Terminate any unused RF ports by attaching 75 ohm terminators (provided). 
• 
A standard length of RG6 coaxial cable is required for installation (3-feet provided). 
Parts Provided in the Kit 
The following table shows the contents of the kit. 
Part
 
Illustration 
Function
 
Surge-Gap Drop Amplifier
 
 
A: Power Port – for powering by a 
coaxial cable connected to the AC 
adapter. 
B: Input Cable Port 
C: Power Inserter/ Output Port 
(Labeled “In PWR + Out RF”) 
D: Output Port Only
 
AC Adapter
 
 
The AC adapter is connected to the 
drop amplifier at port A by the coaxial 
cable (provided). The AC adapter is 
then plugged into an AC outlet.
 
 
Continued on next page