Cisco Headend System Release 2.5 Guia Da Instalação
78-4003191-01 Rev B
Initial Installation of RNCS Software
1-3
Log on to the Sun Fire V240 Server
Introduction
The instructions are to be completed at the remote location. These instructions
assume that the Sun Fire V240 has not yet been configured to serve as a remote
server in the RNCS design.
Logging on to the Sun Fire V240 Server
Follow these instructions to log on to the Sun Fire V240 server.
1.
Connect a laptop computer to the serial network management port of the
Sun Fire V240 server.
2.
Start the HyperTerminal application on the laptop and configure the
application with the following parameters:
•
•
Baud rate—9600
•
Data bits—8
•
Parity—none
•
Stop bit—1
•
Flow control—no
Note: The HyperTerminal application allows one computer to
communicate with another computer.
Result: A HyperTerminal window opens.
Result: A HyperTerminal window opens.
3.
If necessary, power-on the Sun Fire V240 server.
4.
Type #. and then press Enter.
Result: One of the following results occurs:
•
Result: One of the following results occurs:
•
The Login prompt appears.
•
The sc> prompt appears.
5.
Did the Login prompt appear after you completed step 4?
•
•
If yes, follow these instructions.
a) Type admin and then press Enter.
b) Type the admin password and then press Enter.
a) Type admin and then press Enter.
b) Type the admin password and then press Enter.
Result: The sc> prompt appears.
•
If no (the sc> prompt appeared), go to step 6.