Cisco Model GS7000 4-Port Node 1 GHz with 55 70 Split Guia Da Instalação
Model GS7000 GainMaker Node
1x/2x-3x-4x Local Control Module to
Status Monitor Upgrade Instructions
1x/2x-3x-4x Local Control Module to
Status Monitor Upgrade Instructions
Introduction
The Model GS7000 GainMaker
®
Scaleable 4-Port Node can be optionally equipped
with a either a Status Monitor (SM) or a Local Control Module (LCM). For
complete instructions on installing and operating the SM/LCM refer to Model
GS7000 GainMaker Node 1x/2x-3x-4x Status Monitor/Local Control Module Installation
and Operation Guide, part number 4024769.
A Local Control Module can be field upgraded to a Status Monitor through the
A Local Control Module can be field upgraded to a Status Monitor through the
addition of a transponder core module. The transponder core module plugs
directly onto the Local Control Module’s main PWB. The mechanical housing for
the Status Monitor and the Local Control Module are the same.
This document explains the LCM to SM field upgrade procedure for a 4-way
This document explains the LCM to SM field upgrade procedure for a 4-way
LCM, part number 4024775.
The Status Monitor Upgrade Kit, part number 4024777, contains the following
The Status Monitor Upgrade Kit, part number 4024777, contains the following
items:
Transponder core module (1)
Plastic stand-offs (2)
Upgrade instructions (1)
IMPORTANT: This kit can only be used to upgrade a 1x/2x-3x-4x LCM, not to
upgrade an earlier legacy LCM for a 2-way GS7000 node. Make sure the LCM
you are upgrading is a 1x/2x-3x-4x LCM, part number 4024775, which has two
round cut-outs on the front panel, one labeled SM and one labeled LCM, as shown
in Local Control Module Description (on page 2). A legacy 2-way LCM, part
number 4011932, only has one round cut-out on the front panel labeled Local
Control Port. If you need to upgrade a legacy 2-way LCM to a SM, use upgrade
kit part number 4011933 instead.