Cisco DNCS System Release 2.7 3.7 4.2 Guia Do Desenho

Página de 182
 
 
Second Tuner Status Diagnostic Screen 
78-4001708-01 Rev B 
71 
 
Field Name 
Description 
Possible Values 
PCR 
The PID number that is used to 
decode the program clock 
reference (PCR) information 
 
Note: The PCR PID is typically 
the same as the Video PID. 
 
[Channel-dependent] 
PTS 
A presentation time stamp that 
changes each time the screen 
refreshes 
 
[UNIX format]—number should 
change each time the screen 
refreshes 
 
Important! If this number does not 
change each time the screen 
refreshes, then video may have 
been lost. 
PEI 
The number of errors in the 
MPEG stream before reaching 
the Broadband Interface 
Processor 
 
0—desired value 
 
[Integer > 0]—indicates an issue 
PER
The PERs reported by the 
MPEG decoder chip 
 
Digital—0 
 
Analog—0 
SER
10
 
The number of SERs reported by 
the MPEG decoder chip 
 
Digital—0 
 
Analog—n/a 
RST
10
 
The number of times the 
software driver has restarted the 
MPEG decoding process 
 
0—desired value 
 
[Integer > 0] 
 
Note: 
If the RST value is 
incrementing, a source issue could 
exist. Please contact Cisco 
Services. 
 
 
                       
10
 This field is only valid for the standard-definition (SD) set-tops.