Compact EGC Amplifier 93250 
Installation and Setup Instructions 
Application 
The Compact Amplifier type 93250 has one active output and is used in trunk and 
distribution applications. The amplifier can be monitored via the compact 
transponder and the ROSA
 Element Management System. All equalizers and pads 
are electronic and can be set with the handheld terminal type 91200. The plug-in 
filters in the reverse path allow flexible choice of frequency range for both forward 
and reverse path. 
AC connection max.1
5A at 
remote supply 
Power supply fuse  
(2AT at 230V)
(5AT at remote supply) 
Reverse equlizer (plug-in) 
Type 74141-xx 
Input splitter  
Type 74089  0 dB link 
Type 77041  3.5/3.5 dB 
Type 77042  2/6 dB 
Type 77043  1.5/10.5dB 
Fuses (turnable) 
Choose AC-pass 
Terminal for earthing  
DC-voltage indicator  
24 V DC
Test point output 
-20 dB, directional 
Test point input 
-20 dB, bidirectional 
Compact Transponder
Type 91051
/ 91063
Diplex Filter 
Type 75130-xxxx  
If no reverse path wanted; 
Use 0 dB link type 74089 
Mounting fittings 
(total  3 pcs.) 
AUX Plug-in module 
Equalizer     
74100-xxx
Inv.Equalizer     74190-xx
Attenuator   
77150-xx   
0 dB Link 
74069 
Output splitter  
Type 74069  0 dB link 
Type 77041  3.5/3.5 dB 
Type 77042  2/6 dB 
Type 77043  1.5/10.5dB 
Low voltage lockout 
Type 75018-xx 
Reverse Test Point 
-20 dB, directional coupled
Reverse injection Test Point
-20 dB, directionalt 
Diplex Filter 
Type 75130-xxxx  
If no reverse path wanted; 
Use 0 dB link type 74089 
 
Figure 1: Amplifier overview