Receiver Description 
 
 
 
Master, Slave, or Single. When the receiver module is placed in Single operating 
mode, both receiver channels in the module will continue to operate even if the 
optical input level falls below the major alarm threshold. 
Key operating parameters of the receiver and the transmitter at the node can be 
controlled and monitored by an ICIM2 or ICIM2-XD, LCI software, ROSA software, 
CLI commands, or the ICIM Web Interface. See Module Parameter Descriptions (on 
page 109) for details. 
Note: Node data is only available for GS7000 Nodes that have a transponder-less 
LCM installed and an interface cable installed between transmitter and LCM. For 
details, see the Cisco Enhanced Digital Return (EDR) C2185 Transmitter for Compact 
Segmentable Nodes A9020x Installation and Operation Guide
, part number 62-7023683-01. 
Some transmitter data is available in all cases. 
 
Receiver Operating Modes 
The receiver can be configured for any of the following modes of operation: 
 
Single 2:1 
 
Dual 1:1 
 
Dual 2:1 
 
Single 2:1 on Primary + Single 1:1 on Secondary 
 
Single 1:1 on Primary + Single 2:1 on Secondary 
 
Legacy Single 2:1 
 