Operating using ICIM LCD, Continued 
Sub-Menu 1 -- Optical Input Information 
The illustration below shows sub-menu 1 of the OptoStar II 1550 nm optical 
amplifier module - Optical Input Information:   
 
The optical input information sub-menu includes options to set the optical input 
power alarm threshold and a reading of the optical input power.   
The default range of the optical input power alarm threshold is -5.0 dBm ~ 10.0 
dBm, with 0.1 dB step. The cursor stays in the “Low” field by default.   
• 
To configure the lower limit of optical power alarm threshold   
1.  Press SET button to start the configuration; 
2.  Press ▲▼ buttons to change the value, and press SET button to confirm;   
3.  Press ► button to move the cursor to “Set”; 
4.  Press SET button to save the configuration. 
• 
To configure the upper limit of optical power alarm threshold   
1.  Press ▼ button to leave the cursor in the “High” field; 
2.  Press SET button to start the configuration; 
3.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
4.  Press ► button to move the cursor to “Set”; 
5.  Press SET button to save the configuration. 
 
 
Continued on next page 
 
 
OL-29666-02   
Operation 
3-7