General Troubleshooting Information, Continued 
Troubleshooting
 
If the red alarm indicator on the front panel of the module is illuminated, check 
the OptoStar II ICIM display, the OptoStar II console, or the OptoStar II NMS for 
alarm code. See Alarm Code List (on page 3-18) to determine the cause of the 
alarm. See the table below. 
Alarm 
Possible Cause 
Servicing Instruction 
High Bias / 
TEC Current 
Automatic power control 
circuit failure 
Contact the manufacturer for 
servicing 
High Laser 
Temperature 
 
Laser failure 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
Contact the manufacturer for 
servicing 
High Module 
Temperature 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
 
Poor chassis 
ventilation 
 
Chassis fan failure 
 
Ensure good ventilation 
 
Put the chassis in a place with 
good ventilation 
 
In case of fan failure, repair or 
replace the fan, or contact the 
manufacturer for servicing 
Low or High 
Optical Output 
Power 
 
Laser failure 
 
Optical connector 
mismatch 
 
Optical connector 
contains dusts or 
contaminants 
 
Check whether the laser has 
been switched on 
 
Check whether the optical 
connector matches 
 
Make sure all the mating 
surfaces of the fiber are clean 
 
Check whether the optical 
output power is between 
(standard value - 0.2) dBm 
and (standard value + 0.5) 
dBm with an optical power 
meter. 
 
If the problem persists, 
contact the manufacturer for 
servicing 
 
Continued on next page 