Console-Module Control Interface, Continued 
Setup Parameters 
The table below lists the setup parameter of the OptoStar II reverse receiver 
module. 
Setup 
Parameters 
Description 
Factory Default 
Optical Alarm 
Threshold 
Shows/sets optical alarm upper 
limit and lower limit 
Lower limit: - 17.0 
dB 
Upper limit: + 3.0 
dB 
Module Alarm 
Options 
Display/set module alarm options 
Four-way modules 
are all in ON status 
Test Point 
Display/set test points for different 
modules 
No test point 
Alarm ON/OFF 
Shows/sets module alarm status: 
ON/OFF 
The Alarm ON/OFF corresponds to 
the selection of module alarm status, 
for example: When you only need to 
monitor Module 1 and Module 2, the 
Alarm ON/OFF for Module 1 and 
Module 2 will be switched to ON.   
Alarm status: ON 
Four-Way 
Module Gain 
Control Mode   
Shows/sets AGC or MGC gain 
control mode 
Four-way modules 
are all in AGC mode   
(gain in MGC mode 
is set to 0 dB)   
 
 
Continued on next page 
 
 
OL-29664-05 
Operation 
3-27