DSAN Coaxial Cable Pin Connector Installation 
 
Recommended Procedures 
Some field personnel have noted that the pin connector insertion is easier when the 
pin connectors are cut between 1.55 and 1.6 inches in length. The longer length 
allows for the pin to engage the internal spring-loaded contact before the connector 
threads engage the housing. This reduces the required insertion force when working 
to engage the connector threads. It may also help to twist the connector back and 
forth slightly while pressing in against the seizure to get the tip of the pin to engage. 
Important: Do not allow the pin to exceed the 1.6 inch maximum length. We also 
recommend that you file the tip of the cut pin connector smooth to remove any metal 
burrs. 
We recommend that you use one of the following pin cut procedures based on the fit 
of the pin connector in the housing guide: 
 
If the pin connector fits properly in the housing guide, use the tip of the CUT 
arrow label as the cut length. Be careful to not exceed the 1.6 inch maximum 
length. See the preceding illustration for pin connector measurement points. 
 
If the pin connector does not fit properly in the housing guide, use a tape 
measure and cut the pin between 1.55 and 1.6 inches, measuring from the tip of 
the pin to the edge of the pin connector that will sit flush with the housing when 
the pin connector is fully installed. Be careful not to exceed the 1.6 inch 
maximum length. See the preceding illustration for pin connector measurement 
points.