Cisco Cisco Packet Data Gateway (PDG)

Página de 153
   Engineering Rules 
HNB-GW Engineering Rules  ▀   
 
HNB-GW Administration Guide, StarOS Release 16  ▄  
 
   
137 
HNB-GW Engineering Rules 
The following engineering rules apply when the system is configured as an HNB-GW: 
 
A maximum of 16 HNB-GW service can be configured on a system which is further limited to a maximum of 
256 services (regardless of type) can be configured per system. 
 
A maximum of 16 CS-network instances can be configured on system for HNB-GW network function but 
multiple HNB-GW services can be associated with the same CS-network instance. 
 
A maximum of 16 PS-network instances can be configured on system for HNB-GW network function but 
multiple HNB-GW services can be associated with the same PS-network instance. 
 
A particular HNB-GW service can be associated with more than one CS/PS network entity. 
 
A maximum of 12 HNB-SCCP-network instance can be configured on system for HNB-GW network function. 
 
A maximum of 4 HNB-ALCAP service can be configured on system for HNB-GW network function. 
 
A maximum of 4 Radio Network PLMN ids can be configured in an HNB-GW service. 
 
A maximum of 1 RNC id can be configured in a Radio Network PLMN. 
 
A maximum of 1 SeGW IP address can be associated with an HNB-GW service.