Known limitations 
Cisco TelePresence System C-Series Software Release Notes 
Page 17 of 133 
 
 
* To minimize service abruption it will be 
beneficial to upgrade all systems in one go, 
avoiding following the above procedure for 
every endpoints you upgrade. A future TMS 
version will resolve this condition negating the 
need to restart the services. 
 
Workaround to restore the release keys: 
* Once TMS has restored communication with 
the systems, upgrade the units one more time. 
This time TMS will be able to communicate with 
the systems when they boot up and set the 
release keys.  
 
Note: Please read the resolved caveats 
section Reference ID 85930 as well. 
 
Note: The above issues are fixed for TMS 
13.0 
CSCtr32348 
TANDBERG PrecisionHD 1080p Camera 
all SW versions. 
720p50, 720p30 and 720p25 output has no 
CRC included for HD-SDI. Depending on the 
device you connect the camera to, you may not 
get video using this format. The Cisco C/Ex/Mx-
Series codecs will support these formats. 
N/A 
Ver. TC2.1.0 and above 
Startup scripts will not work with Windows end 
of line. You must use Unix end of line to be able 
to run multiple commands. Most editors have 
the option to set which format to use. If you use 
Notepad ++, you can set Unix format in the 
Settings/Preferences menu.  
N/A 
Ver. Any 
If you run cascaded cameras and the chained 
cameras are running an old camera code, we 
have seen that zoom
 
only works when trying to 
control the chained camera. The solution is to 
connect the cascaded camera as the first 
camera in the chain so that the camera is 
detected and upgraded by the codec, or use the 
Ethernet upgrade method. 
N/A 
Ver. Any 
HD-SDI may not work with cables shorter than 
3 meters. This is due to a jitter issue. 
N/A 
Ver.Any 
If you turn off H.323 as the protocol but leave 
default protocol as H.323 you will be unable to 
make outgoing calls unless you edit the URI to 
include 'sip:' in front of the number or change 
the default call protocol to SIP. 
N/A 
Any 
1920*1200p60 output resolution will run in DVI 
compatibility mode and hence audio cannot be 
transmitted over HDMI when using this 
resolution. 
CSCtr32423 
Ver. TC3.x and above 
If you dial a TANDBERG 150 with SW version 
L5.1.1 or older with encryption setting set to 
‘on’, you may not get audio in any direction. 
CSCts34924 
TC3.0.0 and above 
The call status on the web interface will not be 
displayed if you access the codec using 
HTTPS.