Reliability
You expect a technically convincing solution, with the flexibility to adapt to ever
increasing requirements. Easy to operate and designed for easy maintenance.
increasing requirements. Easy to operate and designed for easy maintenance.
Compact Design
UPS electronics and battery are combined in only 2U of rack
space. With the flip-over front cover it is easy to change the
hot-swappable battery or to add external battery packs.
space. With the flip-over front cover it is easy to change the
hot-swappable battery or to add external battery packs.
Autonomy time can be extended
by preconfigured battery packs. The
number of connected battery packs
will be detected automatically. All
battery packs are hot-swappable and
can be connected without discon-
necting the UPS, simply open the
cover to swap.
by preconfigured battery packs. The
number of connected battery packs
will be detected automatically. All
battery packs are hot-swappable and
can be connected without discon-
necting the UPS, simply open the
cover to swap.
Communication options
Extraordinary communication options are provided by the
several interfaces including programmable potential-free
contacts, emergency power off
switch, RS232, USB and an extension
slot that can be used in parallel mode
with RS232/USB. The extension slot is
compatible with optional accessories
such as relay cards or SNMP adapter.
several interfaces including programmable potential-free
contacts, emergency power off
switch, RS232, USB and an extension
slot that can be used in parallel mode
with RS232/USB. The extension slot is
compatible with optional accessories
such as relay cards or SNMP adapter.
Battery management
The improved battery charging technology provides quicker
charging time with a gentle charging
characteristic. The battery manage-
ment system is able to differentiate
between initialization during setup, the
battery charging phase (temperature
compensated) and the standby phase.
This enables the system to extend
battery lifetime as there is a decrease
of pole corrosion. An uncoupled
ment system is able to differentiate
between initialization during setup, the
battery charging phase (temperature
compensated) and the standby phase.
This enables the system to extend
battery lifetime as there is a decrease
of pole corrosion. An uncoupled
battery charger avoids battery heating and inverter reflection
effects.
effects.
Innovative output control
All UPS outlets are equipped with an innovative lock mechanism
that prevents the connected cables from accidental disconnection.
The UPS outlets can be managed by
the user, allowing applications to be
prioritized in the event of a power
failure. These programmable outlets
allow for easy load management or
load shedding, enabling the user full
flexibility in power distribution and
energy management.
that prevents the connected cables from accidental disconnection.
The UPS outlets can be managed by
the user, allowing applications to be
prioritized in the event of a power
failure. These programmable outlets
allow for easy load management or
load shedding, enabling the user full
flexibility in power distribution and
energy management.
Graphical display
The multi-language graphical display supports better read-
ability. It displays several parameters of the input, UPS mode
and the output. Three LEDs at the top of the display indicate
ability. It displays several parameters of the input, UPS mode
and the output. Three LEDs at the top of the display indicate
the current operating mode. From
the control panel the user is able
to configure the UPS setting and
activate an audible alarm. All
events are logged by an internal
logger to allow events analysis.
From the settings menu the user
can control the UPS outputs
according to the battery capacity
and the delay after a power failure
the control panel the user is able
to configure the UPS setting and
activate an audible alarm. All
events are logged by an internal
logger to allow events analysis.
From the settings menu the user
can control the UPS outputs
according to the battery capacity
and the delay after a power failure
for the UPS to initialize a shut down. It is also possible to
schedule for a battery test either daily, weekly or monthly.
schedule for a battery test either daily, weekly or monthly.
Additional features
With the converter mode the UPS can be used as frequency
converter or works as a line conditioner with an effective
output voltage of 200V or 208V.
converter or works as a line conditioner with an effective
output voltage of 200V or 208V.