Miele HR 1924 DF Guia De Especificação
HR 1924 DF / HR 1924 DF LP
Features:
M Touch controls and backlit precision
knobs
ComfortLift panel
M Pro dual stacked burner system with
TrueSimmer
ComfortClean dishwasher-safe grates
TwinPower Convection fans
21 Operating modes including
Self Clean
Moisture plus
MasterChef and MasterChef Plus
automatic programs
Wireless roast probe
Soft Close and Soft Open
Clean Touch Steel
™
front
SPECIFICATIONS
HR 1924 DF
Item 25192451USA
HR 1924 DF LP
Item 25192452USA
Overall Unit Width
29
15
/
16
” (760 mm)
Overall Height
35
1
/
2
” — 37” (901.7 — 939.8 mm)
Overall Unit Depth to control panel
26
1
/
2
” (673 mm)
Oven Door Clearance
22
3
/
4
” (577 mm)
Niche
Minimum Cabinet Niche Width
Minimum Cabinet Niche Width
30” (762 mm)
Minimum Cabinet Opening Height
35
1
/
2
” (901.7 mm)
Burners (G/LP)
M Pro Power Plus - Standard Configuration*
Gas Burners:
(1) 12,500 BTU (G/LP); (3) 19,500 BTU (G/LP)
Total BTU Output
71,000 BTU (G/LP)
Gas
Gas Line Connection
Gas Line Connection
1/2” NPT
Operational Altitudes
High Altitude
Miele Natural Gas and LP Ranges and Rangetops
will function up to 9,800 ft. in altitude without
adjustment; the following exception will function up
to 6,500 ft. in altitude without adjustment:
will function up to 9,800 ft. in altitude without
adjustment; the following exception will function up
to 6,500 ft. in altitude without adjustment:
• Griddle in LP: HR 1136 LP, HR 1936 LP,
HR 1956 LP, KMR 1136 LP, KMR 1356 LP
• Grill in G: HR 1135 G, HR 1935 G, HR 1955 G,
KMR 1135 G, KMR 1355 G
HR 1956 LP, KMR 1136 LP, KMR 1356 LP
• Grill in G: HR 1135 G, HR 1935 G, HR 1955 G,
KMR 1135 G, KMR 1355 G
If an installation exceeds these elevations, please
contact rangejetkit@mieleusa.com.
contact rangejetkit@mieleusa.com.
Plumbing
Water Supply Requirements
An Inline water filter, like activated carbon, is
required to reduce mineral deposits. Do not
connect to a Reverse Osmosis (RO) water system.
Connect to a cold water supply only. Must be
connected to a shut-off valve. The water shut-off
valve must be accessible afterinstallation. The
water pressure must be between 14.5 and 145 psi
(1 and 10 bars). If the pressure is higher, install a
pressurereducing valve. The supplied hose has
a length of 4’ 11” (1.5 m). The hose must not be
shortened. The total hose length must not exceed
24.5 ft. (7.5 m).
required to reduce mineral deposits. Do not
connect to a Reverse Osmosis (RO) water system.
Connect to a cold water supply only. Must be
connected to a shut-off valve. The water shut-off
valve must be accessible afterinstallation. The
water pressure must be between 14.5 and 145 psi
(1 and 10 bars). If the pressure is higher, install a
pressurereducing valve. The supplied hose has
a length of 4’ 11” (1.5 m). The hose must not be
shortened. The total hose length must not exceed
24.5 ft. (7.5 m).
Plumbed Hose Connection
Supplied hose: flexible braided 4’11” (1.5 m) with
3
/
8
” O.D. compression fitting for connection to a
shut off valve
Electrical
Electrical Requirements
120V / 240V, 60Hz, 30 Amps
120V / 208V, 60Hz, 30 Amps
120V / 208V, 60Hz, 30 Amps
Power Cord
NEMA 14-30 plug, 5’ 11” (1.8 m) long
Shipping
Shipping Weight
Shipping Weight
385.1 lbs (174.7 kg)
Shipping Dimensions
37
7
/
16
” (950 mm) W x 52” (1,294 mm) H x 31
1
/
2
”
(800 mm) D
Support
Call Miele
Call Miele
800.843.7231
Miele Website
8
www.mieleusa.com
20/20 Link
8
2020technologies.com
30” Dual Fuel Range
Model: HR 1924 DF / HR 1924 DF LP
Model: HR 1924 DF / HR 1924 DF LP
FOREVER BETTER
HR 1924
Page 2 of 9
Specification Sheet TRS 05022016
* Please note if a BTU-reducing kit is necessary, an authorized installer is required to modify the product to meet ANSI Z21.