Samsung AQV12PSLX Manual Do Utilizador

Página de 42
6
Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the 
Maintaining your air conditioner
  If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
  If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of
  The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can 
be reduced depending on the temperature condition.
  If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
Mode
Indoor  
temperature
Outdoor 
temperature
Indoor 
humidity
Remark
Cooling 
16˚C~32˚C
-10˚C~46˚C
16˚C~46˚C
-10˚C~46˚C
16˚C~46˚C
Relative 
humidity 
80% or less
AQV12/18/24P**
AQV12/18/24P**
AQV12/18/24P**
Heating
27˚C or less
-10˚C~24˚C
-15˚C~24˚C
-
Dry
18˚C~32˚C
-
Mode
Indoor  
temperature
Outdoor 
temperature
Indoor 
humidity
If out of conditions
Cooling 
16˚C~32˚C
-5˚C~46˚C
80% or less Condensation may occur on the indoor unit with risk to have 
 Heating
27˚C or less
-15˚C~24˚C
-
Internal protection triggers and the air conditioner will stop.
Dry
18˚C~32˚C
-5˚C~46˚C
-
Condensation may occur on the indoor unit with risk to have 
Internal protections via the unit control system
 This internal protection operates if an internal fault occurs in the air conditioner.
Model : RJ
Type
Description
Against cold air
De-ice cycle
Protect compressor
The air conditioner does not start operating immediately to protect the compressor of the 
outdoor unit after it has been started.
•   If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may 
have deposited at low temperatures. 
Checking before use