Samsung NV3000H Электрический духовой шкаф с технологией Dual Fan, 70 л Manual Do Utilizador

Página de 30
English - 9
installation
Safety instructions for installation
This oven may be installed only by an approved electrician. The installer is responsible for 
connecting the appliance to the main supply, while observing the relevant safety regulations.
•  Ensure protection from live parts when installing the oven.
Power connection
If the appliance is not connected to the mains with a plug, a multi-pole isolator 
switch (with at least 3 mm contact spacing) must be provided in order to satisfy 
safety regulations. The power cable (H05 RR-F or H05 VV-F, min. 1.5~2.5 mm²) 
must be of sufficient length to be connected to the oven, even if the oven stands 
on the floor in front of its built-in cabinet. Open the rear connection cover of 
the oven with a screwdriver and loosen the screws of the cable clamp before 
you connect the power lines to the relevant connection terminals. The oven is 
earthed via the (   )-terminal. The yellow and green cable (earth connection) 
must be connected first and be longer than the others. If the oven is connected 
to the mains with a plug, this plug must remain accessible after the oven is 
installed. Samsung will take no responsibility for accidents that originate from a 
missing or faulty earth connection.
WARNING: Do not allow the connecting cable to become trapped during installation, and 
prevent it coming into contact with hot parts of the oven.
Installation in the cabinet
With built-in furniture, plastic surfaces and adhesive for the oven should be resistant to 90 °C inside of 
the furniture and to 75 °C for adjacent furniture. Samsung will take no responsibility for damage of plastic 
surfaces or adhesive from the heat.
There should be a ventilation gap in the base of the kitchen cabinet where the oven is to be placed. For 
ventilation, a gap of about 50 mm should be left between the lower shelf and the supporting wall. If the 
oven is to be installed below a hob, the hob’s installation instructions should be followed.
595
370
560
545
21
595
Max.50
Min.550
Min.560
Min.50
Min.590 ~ Max.600
Min.460 x Min.50
Built-in
572 550
 
595
370
560
545
21
85
595
175
Max. 
494
Min.550
Min.560
Min.600
Min.460 x Min.50
Built-under
Built-in + Built-under
572 550
Max. 506
Push the appliance completely into the cabinet and fix the oven firmly on both sides using 2 screws. Make 
sure that a gap of at least 5 mm should be left between the appliance and the adjacent cabinet.
After installation, remove the vinyl protective film, tape, paper and accessories from the door and inside 
of oven. Before uninstalling the oven from the furniture, disconnect the oven from the power supply and 
release the 2 screws on the both sides of the oven.
WARNING: The built-in furniture must have a minimum ventilation gap for Air-flow as shown 
in picture. Do not cover this hole with strips of wood, for this is used to provide ventilation.
The front exterior of the oven such as handle is different model by model. But the size of the 
oven in the picture is same.
BROWN 
or BLACK
BLUE or 
WHITE
YELLOW 
and GREEN
02
  MAINTENANCE & INS
TALLA
TION
Neo Lite_NV70H3340BS_WT_DG68-00591B-01_EN.indd   9