ademco vista-20ps Manual Do Utilizador

Página de 64
 
– 39 – 
Event Logging Procedures 
 
About Event Logging 
The system records various events in a history log, which can be viewed by the master 
user on an Alpha Display keypad.  
• The Event Log holds up to 100 (VISTA-20P/PS Series) or 50 (VISTA-15P Series) 
events. 
• Events are displayed in chronological order, from most recent to oldest. 
• When the log is full, the oldest event is replaced by the logging of any new event. 
 
Viewing the Event Log 
 
1.                    + [#] +  [6] + [0] 
 (Master 
Code)
  
Alpha Displays: 
✱✱✱✱
DISARMED
✱✱✱✱
 
READY TO ARM 
 
 
 
2.  The system displays the most recent event as follows: 
  • event number 
  • type of event, identified by its corresponding code  
 
(refer to the code table that follows) 
  • zone or user number (depending on type of event) 
  • partition in which event occurred 
  • time and date of the event’s occurrence. 
3. Pressing [∗] displays previous events (back in time). 
  Pressing [#] displays events forward in time. 
4.  Exit the event log by pressing any key other than [∗] 
or [#]. 
001  E441 U001  P1 
12:34AM  01/02/00 
 
 
 
Understanding the Type of Event Displayed 
If the event code is preceded by an E (as in the above display), it means that the 
event is new and ongoing; if preceded by an R, it means the event has been restored. 
 
 
Code 
Definition 
110 Fire 
Alarm 
121 Duress 
122 Alarm, 
24-hour 
Silent 
123 Alarm, 
24-hour 
Audible 
 
 
Code 
Definition 
131 Alarm, 
Perimeter 
132 Alarm, 
Interior 
134 Alarm, 
Entry/Exit 
135 Alarm, 
Day/Night