Acumen sp500 Manual Do Utilizador

Página de 6
 
 
Electrical Connections 
 
Speedometer 
Wire 
Colour 
   
Purpose 
 
Red/Black 
 
Ignition – a circuit which has 12V when the ignition is switched on AND 
 
 
 
also connect to the Red wire of the Speedo reader 
 
Red 
 
 
12V – permanent power supply 
 
Black/Green   
LED Indicator number 2 – switches to ground/earth/0V 
 
White   
 
LED Indicator number 3 – switches to 12V 
 
Black 
  Ground/earth 
AND 
 
 
 
also connect to the Green wire of the Speedo reader 
 
Blue   
 
LED Indicator number 5 – switches to 12V 
 
Yellow  
 
Speedometer signal – connect to the BLUE wire of the Speedo head reader 
 
Blue/Black 
 
LED Indicator number 4 – switches to ground/earth/0V 
 
Green   
 
LED Indicator number 1 – switches to 12V 
 
 
 
 
NOTE! If you are using one 12V switched for both the left and right m/c indicator lights you will need to 
fit two diodes in the circuit thus;  
 
Diodes are available from Acumen Electronics 
Free of Charge on Request – or from any  
Electronics stockist. 
M/c Ind Light 
M/c Ind Light 
Speedo 
 
Using it
 
 
 
Knowing the controls 
INC button 
MOD Button 
As the name suggests; 
 
The MODE Button –  
It increases values of the Trip  
 
This changes from ODO to TRIP to CLOCK 
and also sets the speedometer ratio 
or Clock or Speedo ratio 
 
 
 
 
 
DEC button 
 
As the name 
suggests; 
 
 
It decreases 
values of the 
Trip or Clock or 
Speedo ratio 
UNIT button 
 
As the name suggests; 
 
It changes the Speedo, 
trip and ODO from  
 
 
 
Miles to Kilometers and 
vice/versa 
 
 
 
 
Page 4