Alcatel-Lucent omniacces-voip gateway Manual Do Utilizador

Página de 430
 VoIP Commands
Page 5-155
Command Usage
Set signal strength threshold level for single (frequency) tone detection.
Syntax Options
voice signaling single frequency tone detection threshold level
voice signaling channel <
slot/port/startChannel-endChannel
 > single frequency tone detection 
threshold level <
value 
>
Definitions:
slot
Specifies chassis slot number where VSM is installed, (e.g., 
2
).
port
Specifies physical port number on voice daughtercard, (e.g., 
1
).
startChannel
The first number in the range of voice channels (e.g., 
1
).
endChannel
The last number in the range of voice channels (e.g., 
30
). 
 Syntax Note 
Be sure to separate the start and end range numbers with a 
hyphen (e.g., 
1-30
).
value
Specifies the signal frequency threshold level for tone detection, in dBm (decibels below 1 
milliwatt; output signal power referenced to 1 milliwatt input signal power), from
-50 
to
 -15, 
(e.g., 
-40
).
Default:
The default value is 
-40
 dBm.
Command Examples:
voice signaling channel 2/1/1-12 single frequency tone detection threshold level -40
voice signaling channel 2/2/13-24 single frequency tone detection threshold level -50