The System Options
 
 
AXIS 230 
 
38 
The Factory Default Settings
In certain circumstances, it may be necessary to reinstate the Factory Default settings for 
your AXIS 230. This is performed in one of two ways:
• By clicking the 
Restore button from the Maintenance page under System Options. This 
action will reset most of the unit’s parameters but will save the IP-address, the Subnet 
mask and the Default Router.
• By pressing the 
Reset button, located on the rear panel. This option will reset ALL the 
parameters currently configured in the unit, i.e. network settings, events, etc.
Follow the instructions below to reinstate the product factory default settings using the 
Reset button:
1. Switch off the AXIS 230 by disconnecting the power supply.
2. Press and hold the Reset button, and reconnect the power.
3. Keep the button pressed until the Status Indicator displays yellow (note that this may 
take up to 15 seconds), then release the button. When the Status Indicator displays 
green (which can take up to several minutes) the AXIS 230 will then have been reset to 
its original factory default settings.