3com 2000 TR Manual Do Utilizador

Página de 58
C
TR-
IN
-FE M
ODULE
 T
ECHNICAL
 S
PECIFICATIONS
Environmental Specifications
TR-in-FE Cable Specification
The TR-in-FE cable you connect to the TR-in-FE 
Module must conform to the Multi-Mode Fiber 
(MMF-PMD) standard defined by ANSI x.3-166-1992.
3Com supports multi-mode fiber (MMF-PMD) 
62.5/125 mm for full duplex mode. The maximum 
inter-station distance (including device-to-network 
connectors) should not exceed 2 kilometers (1.25 
miles). 
For half duplex mode, the cable length should not 
exceed 300 meters.
See the following table for cable specifications:
Environmental Requirements
Operating Temperature
0 to 50˚ C (32 to 122˚F)
Operating Humidity
10 to 95% relative humidity, non-con-
densing
Standards
EN60068 (IEC68)
Safety
Agency Certifications
UL 1950, 
EN60950, 
CSA 22.2 No. 950, 
ECMA 97
Electromagnetic Emissions
(Agency Certification)
EN55022 Class B, 
FCC Part 15 Class A, 
C108.8-M1983 Class A, 
EN 50082-1 (IEC801 Parts 2-5), 
EN60555 Part 2 
Specification
Description
Core
62.5 
mm diameter
Cladding
125 
mm diameter nominal
122 
mm minimum
128 
mm maximum
Numerical aperture
0.275
Maximum attenuation
11 dB (including 1 db allowed for 
reflection and dispersion penalties)
Modal bandwidth
500 MHz.km
Maximum distance between 
nodes
2 km (1.25 miles)