5 Specifications
Type:
1-inch large-diaphragm backplate pressure
gradient microphone
Polar patterns:
cardioid
Open-circuit sensitivity:
20 mV/Pa (-34 dBV)
Frequency range:
20 to 20,000 Hz (see frequency 
response graphs)
Impedance:
≤ 200 ohms
Recommended load impedance:
≥ 1000 ohms
Bass cut filter slope:
6 dB/octave at 160 Hz
Preattenuation pad:
0/-20 dB (switchable)
Equivalent noise level to IEC 60268-4 (A-weighted):
13 dB(A) (0 dB preattenuation)
Signal/noise ratio re 1 Pa (A-weighted):
81 dB
Max. SPL for 0.5% THD:
136/156 dB SPL (0/-20 dB)
Dynamic range (A-weighted):
123/143 dB (0/-20 dB)
Environment:
temperature: -10°C to +60°C
R.H.: 95% (+20°C); 85% (+60°C)
Powering:
12 to 52 V phantom power 
to IEC 61938
Current consumption:
< 2 mA
Connector:
IEC standard 3-pin XLR 
Dimensions:
54 x 43 x 160 mm / 2.1 x 1.7 x 6.3 in.
Net weight:
290 g / 10.2 oz.
This product conforms to the standards listed in the Declaration of Conformity. To order a free copy of the De-
claration of Conformity, visit http://www.akg.com or contact sales@akg.com.
28
C 214