Ask Proxima DP1000X Manual Do Utilizador

Página de 13
ASK Proxima Lamp Information Guide
DP5800
650
2000 Hours
Press and Hold the "Reset" button on the keypad or the 
"Timer" button on the remote for three seconds.  The 
lamp hours used will be displayed.
Press and Hold the "Reset" button on the keypad or 
"Timer" on the remote control for three seconds, and 
the lamp hours used will be displayed.  Release 
button.  While the Lamp Time is being displayed, 
press the "Reset" button on the keypad or the 
"Menu" button on the remote.  Use the Left Arrow 
Button on the keypad or the Mouse disk on the 
remote to choose "0" on the screen.  Press and Hold 
the "Reset" button for three seconds. The lamp timer 
will be reset.
DP5900
700
2000 Hours
Press and Hold the Up Arrow Button on the Keypad for 
40+ seconds.  The displayed Data value will be the 
hours remaining on the lamp.
Press the Menu Button, choose Setting, then choose 
"Lamp Age" and select.  You will be asked to confirm 
the reset.
DP5950
1250
1500 Hours
Press and Hold the Up Arrow Button on the Keypad for 
40+ seconds.  The displayed Data value will be the 
hours remaining on the lamp.
Press the Menu Button, choose Setting, then choose 
"Lamp Age" and select.  You will be asked to confirm 
the reset.
DP6150
1400
2000 Hours
Press the Menu Button, then choose Advanced, then 
Service.  Select Info.
Press the Menu Button, choose Advanced, then 
choose Service, then Reset Lamp Timer and Press 
Select.  Note: You must have an active source 
connected and displayed on the projector in order to 
reset the lamp.
DP6155
2000
2000 Hours
Press the Menu Button, then choose Advanced, then 
Service.  Select Info.
Press the Menu Button, choose Advanced, then 
choose Service, then Reset Lamp Timer and Press 
Select.  Note: You must have an active source 
connected and displayed on the projector in order to 
reset the lamp.
DP6500x
2500
2000 Hours
Press the Menu button and choose About.  If the 
maximum lamp time of 2000 hours is exceeded, the 
lamp will not light.  The lamp must be replaced and the 
lamp timer reset before the projector will operate.
Press the Menu Button, choose Settings, then 
choose Service, then Lamp Reset.  At 2000 hours, 
the lamp will not light (Lamp Error LED will be On).  
You must press and hold the "Volume -" button and 
then press the "Volume +" button within three 
seconds.  LED on keypad will reset, and you can 
power the lamp on.
Copyright InFocus Corp.
4