Appendix A - Specifications
 
 152-388-100-02, Issue 2
48
June 6, 2000
 H2TU-C-388 List 1
A
PPENDIX
 A - S
PECIFICATIONS
Power
Line Voltage
0, -185 Vdc
CO Supply
-48 Vdc nominal (-42.5 Vdc to -56.5 Vdc) 
(See 
 and 
Electrical Protection
Secondary surge and power cross protection on HDSL2 ports. Requires external 
primary protection.
Fusing
Internal; connected to “FUSE ALARM” output on pin 117
Environmental
Operating Temperature
-40 °F to +149 °F (-40 °C to +65 °C)
Operating Humidity
5% to 95% (non-condensing)
Physical
Height
3.62 in. (9.2 cm)
Width
0.69 in. (1.8 cm)
Depth
10 in. (25.4 cm)
Weight
0.5 lbs. (.23 kg)
Mounting
DDM+ high-density shelf
HDSL2
Line Rate
1.552 Mbps Overlapped Pulse Amplitude Modulation Transmission with Interlocking 
Spectra (OPTIS)
Transmission
Full duplex
Media
One non-loaded, copper, two-wire cable pair
Output
+16.8 dBm ±0.5 dB at 135
Ω 
(0-450 kHz)
 
at CO side; 
+16.5 dBm ±0.5 dB at 135
Ω 
(0-350 kHz) at remote side
Line Impedance
135 
Ω
Maximum Loop Attenuation
35 dB at 196 kHz, 135
Ω
Start-up Time
30 seconds (typical), 1 minute (maximum)
DSX-1
DSX-1 Line Impedance
100 
Ω 
DSX-1 Line Rate
1.544 Mbps ±200 bps
DSX-1 Line Format
Alternate Mark Inversion (AMI) or Bipolar with 8-Zero Substitution (B8ZS)
DSX-1 Frame Format
Extended SuperFrame (ESF), SuperFrame (SF), or Unframed (UNFR)
DSX-1 Pulse Output
6 V
pk-pk
 pre-equalized for 0 to 655 feet of ABAM cable
DSX-1 Input Level
+1.5 to -7.5 dB DSX
System
One-way DS1 Delay
<400 µs over the span
Wander (Looped)
Meets MTIE T1.101 requirements
Wideband Jitter (Looped)
0.2 UI maximum
Narrowband Jitter (Looped)
0.1 UI maximum