HP ml310 Manual Do Utilizador
114
HP ProLiant ML310 Generation 3 Server User Guide
Environmental specifications
Specification Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-10
°
C to 60
°
C (14
°
F to 140
°
F)
Maximum wet bulb temperature 28
°
C (82.4
°
F)
Relative humidity
(noncondensing)**
(noncondensing)**
Operating
20% to 80%
Non-operating
20% to 90%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m
(1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
(1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C
(113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.
(113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.