Fujitsu PRIMERGY TX100 S2 VFY:T1002SX010IN/B4 Ficha De Dados
Códigos do produto
VFY:T1002SX010IN/B4
Datasheet
Fujitsu PRiMERGY tX100 s2 sERvER
Page 4 / 6
http://ts.fujitsu.com/Primergy
DRIve BaYs
Hard disk bay configuration
2 or 4 depending on chosen base unit (3.5” easy change SATA). It is not possible to upgrade the system in the field from 2
to 4 hard disks.
to 4 hard disks.
notes accessible drives
1 bay occupied by DVD/DVD-RW 1x 3.5
DRIve BaYs (Base unIt sPecIFIc)
hard disk bays
2
4
GeneRal soFtwaRe InFoRMatIon
Fan configuration
Silent system fans
Fan notes
Non hot-plug
oPeRatInG Panel
operating buttons
On/off switch
status leDs
Power (green)
ceRtIFIeD oR suPPoRteD oPeRatInG sYsteMs
Certified or supported operating
systems
systems
Microsoft
®
windows server
®
2008 R2 (containing Hyper-V)
Microsoft
®
windows server
®
2008
Microsoft
®
windows server
®
2003 R2
Novell SUSE Linux Enterprise Server
Red Hat Enterprise Linux
Note: Support of other Linux derivatives on demand
Red Hat Enterprise Linux
Note: Support of other Linux derivatives on demand
operating system release link
http://docs.ts.fujitsu.com/dl.aspx?id=a9e600b9-e4cb-4f48-aa41-632f69058421
seRveR ManaGeMent
standard
ServerView Installation Manager
server Management notes
Regarding Operating System dependencies and product details for ServerView Suite Software Products see dedicated
Product Data sheets.
Product Data sheets.
DIMensIons / weIGht
Floor-stand (w x D x h)
203 x 386 x 390 mm
weight
12 kg
envIRonMental
noise emission
According to ISO9296
sound pressure (lpam)
24 dB(A) (idle)/ 24 dB(A) (operating)
sound power (lwad; 1B = 10dB)
3.9B (idle)/ 3.9B (operating)
operating ambient temperature
10 - 35°C
operating temperature note
ETSI 300 019-2-3 Class 3.1
operating environment
FTS 04230 – Guideline for Data Center (installation locations)
operating environment link
http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
electRIcal values
Power supply configuration
1
standard power supply output
250 W
Rated voltage range
100 - 127 V / 200 - 240 V
Rated frequency range
47 - 63 Hz
Rated current max.
100 V – 240 V / 6.0 A – 3.0 A
Rated current in basic configuration
100 – 240 V / 1,5 – 0,6 A
Active power (min. configuration)
26 w
Active power (max. configuration)
171 W
Apparent power (max. configuration) 171 VA
heat emission
heat emission
615.6 kJ/h (583.5 BTU/h)
Power supply notes
Fujitsu patented 0-Watt standby technology
coMPlIance
Germany
Gs
europe
CE Class A *
usa/canada
CSAc/us
ULc/us
FCC Class A
ULc/us