Sony MDS-JB930 Manual Do Utilizador

Página de 61
59
GB
Additional Information
Menu item Sub-item Function
Parameters
Factory setting Reference page(s)
F.in
Sets the duration of Fade-in Play and Recording.
1.0 to 15.0s
5.0s
45
F.out
Sets the duration of Fade-out Play and Recording.
1.0 to 15.0s
5.0s
45
Pitch
Changes the playback speed by auto steps.
–48 to +2
0
43
Pfine
Fine controls the playback speed.
–98.5 to +12.5%
0.0%
44
Sleep
Sets the duration of Sleep Timer.
30/60/90/120min 60min
45
Sleep
Turns Sleep Timer on or off.
On/Off
Off
45
Keyboard ? Type
Selects the type of the keyboard connected to the deck.
US/JP
US
49
Assign ?
Assigns a character to the keyboard connected to the deck. —
52
Clock Set ?
Sets the clock.
8
To recall a factory setting
Press CLEAR while selecting the parameter .
Self-Diagnosis Function
The deck’s self-diagnosis function automatically checks the condition of the MD deck when an err or occurs, then issues a
three-digit code and an err or message on the display .  If the code and message alternate , find them in the following table
and perform the indicated countermeasur e.  Should the problem persist, consult your nearest Sony dealer .
Three-digit code/Message
Cause/Remedy
C11/Protected
The inserted MD is record-protected.
,
 Take out the MD and close the record-protect slot (page 19).
C13/REC Error
The recording was not made properly.
,
 Set the deck in a stable surface, and repeat the recording procedure.
The inserted MD is dirty (with smudges, fingerprints, etc.), scratched, or substandard in quality.
,
 Replace the disc and repeat the recording procedure.
C13/Read Error
The deck could not read the TOC on the MD properly.
,
 Take out the MD and insert it again.
C14/Toc Error
The deck could not read the TOC on the MD properly.
,
 Insert another disc.
,
 If possible, erase all the tracks on the MD (page 35).
C71/Din Unlock
The sporadic appearance of this message is caused by the digital signal being recorded.  This will not affect
the recording.
While recording from a digital component connected through the DIGITAL IN connector, the digital
connecting cable was unplugged or the digital component turned off.
,
 Connect the cable or turn the digital component back on.