Omnitron iConverter Single-Fiber CWDM/AD 8878-35 Manual Do Utilizador
Códigos do produto
8878-35
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • info@omnitron-systems.com • 140 Technology Dr. • Irvine, CA 92618
Trademarks are owned by their respective companies.
iConverter
and
NetOutlook
are registered trademarks of Omnitron Systems Technology, Inc.
Specifications subject to change without notice. ©2009 Omnitron Systems Technology, Inc. All rights reserved.
091-18870-001C
091-18870-001C
7/09
OrdErINg INfOrMATION
Model Type
Model Number
Channel Port
ITU Center Wavelength (nm)
Tx/Rx
Insertion
Loss
Adjacent
Channel Port
Isolation
Non-adjacent
Channel Port
Isolation
Return Loss
(filtered channel)
2-Channel
MUX/DEMUXs
8870-0
1471/1491, 1511/1531
<1.9dB
>30dB
>40dB
>45dB
8871-0
1491/1471, 1531/1511
<1.9dB
>30dB
>40dB
>45dB
8872-0
1551/1571, 1591/1611
<1.9dB
>30dB
>40dB
>45dB
8873-0
1571/1551, 1611/1591
<1.9dB
>30dB
>40dB
>45dB
4-Channel
MUX/DEMUXs
8874-0
1271/1291, 1311/1331, 1351/1371, 1431/1451
<2.4dB
>30dB
>40dB
>45dB
8875-0
1291/1271, 1331/1311, 1371/1351, 1451/1431
<2.4dB
>30dB
>40dB
>45dB
8876-0
1471/1491, 1511/1531, 1551/1571, 1591/1611
<2.4dB
>30dB
>40dB
>45dB
8877-0
1491/1471, 1531/1511, 1571/1551, 1611/1591
<2.4dB
>30dB
>40dB
>45dB
1-Channel
OADM
8878-XX
See below
<1.9dB
>30dB
>40dB
>45dB
s
Single-fiber CWDM/X models must be used in pairs. The Tx wavelengths on one end has to match the Rx wavelengths on the other.
Channel Port - ITU Center Wavelength (nm)
Wavelength Pairing
Tx/Rx
27 = 1271/1291
47 = 1471/1491
31 = 1311/1331
51 = 1511/1531
35 = 1351/1371
55 = 1551/1571
39 = 1391/1411
59 = 1591/1611
43 = 1431/1451
1-Channel CWDM/AD
8878 - xx
8878 - xx
Consult factory for customized CWDM models
SPECIfICATIONS
Model Type
Single-Fiber CWDM/X MUX/DEMUX
Channels
2 Channel
4 Channel
4 Channel
Common Link
Single-Fiber
Connectors
LC (UPC)
Dimensions
W: 0.85” x D: 4.5” x H:2.8”
Weight
12 oz.
Compliances
UL, CE, FCC Class A
Power Requirements
Not powered for non-managed applications
0.025A max @ 3.3VDC for managed applications
Temperature
Standard: 0 to 70
o
C
Storage: -40 to 80
o
C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4,000m
MTBF (hrs)
> 1,000,000 hrs
Model Type
Single-Fiber CWDM/AD Add/Drop MUX
Channels
1 Channel
Common Link
Single-Fiber
Connectors
LC (UPC)
Dimensions
W: 0.85” x D: 4.5” x H:2.8”
Weight
12 oz.
Compliances
UL, CE, FCC Class A
Power Requirements
Not powered for non-managed applications
0.025A max @ 3.3VDC for managed applications
Temperature
Standard: 0 to 70
o
C
Storage: -40 to 80
o
C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4,000m
MTBF (hrs)
> 1,000,000 hrs
Page 3