Nokia 3210 Manual Do Serviço

Página de 70
PAMS
Technical Documentation
NSE 8/9
Service Software Instructions
Page 26
Issue 1 07/99
AGC, DAC, Voltage and Difference. The difference column shows the
difference between tuned DAC values and mean straight line calculated
from part slopes in dBs (see  /1/). This can be calculated when all
measurement results have been received from phone.
Repeat button (ALT+R):
The measurement can be started again by pressing this button.
Save button (ALT+S):
Dialog is closed and tuning 
is saved
 to phone.
Cancel button (ESC):
Dialog is closed and tuning 
is not saved
 to phone.
When calibration is ended, the DAC value checking is made and if it is not
succeeded, error message is shown.
When exit is made, the next selections are set to the values which were
selected before this adjustment.
Operation Mode
Update RF Information window
The exit and the use of AGC–control values is done same way as exit
from power level tuning and power coefficient use:
Tx Power... command
Activation
Status Bar Text
Alt, T,P
Open TX Power Tuning dialog box
Starts TX power tuning.
Before the TX power tuning starts the DC/DC converter is set to the mode
specified in TESLA.INI in the section:
[NSE–8TXPOW]
DC2DC_Startup=2
;0=Auto Mode 1=Abs Mode and 2=Max
Mode
Max Mode is the default mode set at installation time and is recommended
because it will ensure, that the phone will not shut down due to too big
supply voltage drops when tuning the higher power levels.