Panasonic 35 Manual Do Utilizador

Página de 69
13  Troubleshooting 
 
 
 
57 
Symptoms 
Checks/Remedies 
LED does not irradiate. 
Did you select the target channel for the product type? (When selected, the channel 
switch is lit or flashing.) 
→Select the target channel when setting the product type. 
If the target channel is selected but does not irradiate, check if the irradiation time 
is set to 0.0sec for the channel program for the target product type. 
→If so, set the irradiation time to 0.0sec or longer. 
When a warning message is displayed: 
  
 
Temperature warning 
The  channel  connection  indicator  changes  to  orange  (mixture  of  green  and  red) 
when the LED head temperature has reached the warning level. If you continue the 
operation in this condition, the product life will be significantly shortened, and the 
temperature may exceed the upper limit, causing an emergency stop. 
→Set the UV intensity level (%) lower or improve the heat radiation performance 
of the LED head to keep the temperature lower than the warning level. 
Time warning 
When  the  total  irradiation  time  of  the  LED  reaches  the  point  30  hours  before  the 
preset LED replacement point, the time warning is issued and  “x100hrs” will be 
lit. When the time reaches the LED replacement point, the irradiation process will 
make an emergency stop. 
→Prepare a new LED head. After replacement, clear the total irradiation time. 
When an error occurs: 
  
 
Interlock emergency stop 
“ The  interlock  contact  was  opened 
during irradiation.” 
The emergency stop contact was opened during irradiation. 
→Check the emergency stop contact or the external input terminal block. 
Close the contact and then restart irradiation. 
* If the emergency stop contact is open, normal resetting is not available. 
Hold down SET to forcibly reset the interlock. 
Connection error 
“The  LED  was  disconnected  during 
irradiation.” 
It is possible that the connection cable or LED head was broken. 
→Reset the error status, check the connection of the cable and LED head with the 
channel in question, and replace them if necessary. 
LED wire broken 
“LED  circuit  opening  was  detected 
during irradiation.” 
The  current  detection  was  stopped  during  irradiation.  It  is  possible  that  the 
connection cable or LED head was broken. 
→Reset  the  error  status,  check  the  connection  of  the  connection  cable  and  LED 
head with the channel in question, and replace them if necessary. 
LED short-circuited 
“ LED  short-circuiting  was  detected 
during irradiation.” 
An  overcurrent  was  detected  during  irradiation.  It  is  possible  that  the  connection 
cable or LED head was short-circuited. 
→Reset the error status, check the connection of the cable and LED head with the 
channel in question, and replace them if necessary. 
LED temperature error 
“ The  LED  temperature  reached  an 
abnormal temperature.” 
The LED temperature exceeded the upper limit. 
→Set the UV intensity level (%) lower or improve the heat radiation performance 
of the LED head to keep the temperature lower than the warning level. 
LED time error 
“The total irradiation time reached the 
replacement point.” 
The  total  irradiation  time  of  the  LED  reached  the  preset  LED  replacement  point. 
(Or, it is possible that the LED replacement point was set ahead the total irradiation 
time.) 
→Reset the error status, replace the LED head, and then clear the total irradiation 
time. (Or, go to the mode setting screen and correctly set the LED replacement 
point.) 
LED calibration error 
“Calibration uncompleted” 
Calibration was stopped before completion. Or, the calibration was not successful. 
It is possible that the setting is too high, or there is a problem in the dedicated UV 
sensor (option). 
→Reset the error status, check the connection of the UV sensor, review the setting, 
and then retry calibration.