Panasonic AJ-HD150 Manual Do Utilizador

Página de 102
– 65 –
USER menu
<TIME CODE>
Item
Setting
No.
Superimposed
No.
Superimposed
Description
display
display
500
VITC
0000
BLANK
BLANK
0001
   THRU
501
VITC
0000
10L
POS-1
:
:
0006
   16L
:
:
.0010
20L
502
VITC
0000
10L
POS-2
:
:
0008
   18L
:
:
0010
20L
503
REGEN
0000
   REGEN
0001
PRE
504
RUN MODE
0000
        REC
0001
FREE
505
TCG
0000
  TC&UB
REGEN
0001
TC
0002
UB
506
REGEN
0000
   AS&IN
MODE
0001
ASSEM
0002
INSRT
0003
SW
508
BINARY
0000
   000
GP
0001
001
0002
010
0003
011
0004
100
0005
101
0006
110
0007
111
The underline on the setting item denotes the initial setting.
For selecting whether to output the VITC signal at the posi-
tions selected by setup menu items No. 501 (VITC POS-1)
and No. 502 (VITC POS-2).
0: VITC signals are not output.
1: VITC signals are output.
For setting the position where the VITC signal is to be inserted.
This sets the position where the VITC signal is to be inserted.
<Notes>
• The same line as the one used for the setup menu item
No. 502 (VITC POS-2) setting cannot be set.
• This setting takes effect only with the SD output.
This sets the position where the VITC signal is to be inserted.
<Note>
• The same line as the one used for the setup menu item
No. 501 (VITC POS-1) setting cannot be set.
• This setting takes effect only with the SD output.
This sets the synchronization of the internal time code
generator.
0: The time code reader is synchronized with the time code
read from the tape.
1: What the time code generator will be synchronized with can
be preset using either the operation panel controls or the
remote controller.
This sets the operation mode in which the time code of the
internal time code generator is to advance.
0: The time code advances only during recording.
1: It advances while the power is on regardless of the mode
which has been established.
This selects the signal to be regenerated when the TCG (time
code generator) is in the REGEN mode.
0: Both the time code and user’s bit are regenerated.
1: Only the time code is regenerated.
2: Only the user’s bit is regenerated.
This selects whether the time code is to be regenerated during
automatic editing using the unit’s control panel.
0: The time code is regenerated with assemble or insert
editing.
1: The time code is regenerated with assemble editing.
2: The time code is regenerated with insert editing.
3: The setup menu item No.503 (REGEN) setting is followed.
This sets the usage status of the user bit of the time code
generated by the TCG.
0: NOT SPECIFIED (character set not specified)
1: ISO CHARACTER (8 bits character set based on ISO646,
ISO2022)
2: UNASSIGNED 1 (undefined)
3: UNASSIGNED 2 (undefined)
4: UNASSIGNED 3 (undefined)
5: PAGE/LINE
6: UNASSIGNED 4 (undefined)
7: UNASSIGNED 5 (undefined)
Setup menus