Cooling Characteristics
(RH : 46%, Indoor fan speed : High fan)
(230V, 60Hz)
•  This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on 
  the indoor unit type.
•  Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value.
  (In this case, be sure to stop all the indoor units where performance is not being checked.)
•  The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary.
NOTE
Outdoor Unit   CU-4KS31NBU    Indoor Unit   CS-MKS12NB4U ×
1
(1) Low pressure performance chart
(2) Operating current performance chart
(3) Indoor discharge air performance chart
Low pressure at wide tube service valve
psig (MPaG)
Outdoor air temperature °F (°C)
146
(1.0)
174
(1.2)
118
(0.8)
90
(0.6)
Lo fan
Hi fan
Hi fan
HH fan
Operating current (A)
Outdoor air temperature °F (°C)
4
5
6
Indoor discharge air temperature °F (°C)
Outdoor air temperature °F (°C)
Lo fan
Hi fan
Hi fan
HH fan
Lo fan
Hi fan
Hi fan
HH fan
77
(25)
86
(30)
95
(35)
104
(40)
77
(25)
86
(30)
95
(35)
104
(40)
77
(25)
86
(30)
95
(35)
104
(40)
46.4(  8)
42.8(  6)
68.0(20)
64.4(18)
60.8(16)
57.2(14)
53.6(12)
50.0(10)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)